| Model No.: SF100-5/6 |
| Items |
Parameter |
| Input Voltage: |
AC 220 V± 10% 50 Hz / 60 Hz |
| Input Power: |
No-load: |
SF100-5 |
SF100-6 |
| |
|
70W |
80W |
| |
Full-load: |
SF100-5 |
SF100-6 |
| |
|
750W |
900W |
| Applicable Battery Types: |
6 V, 12 V, 16 V, 18V Storage Batteries |
| Functions: |
Charge |
| |
Discharge |
| |
Auto cycle charge and discharge |
| |
Pulse repair |
| |
Data record and inquire |
| Voltage |
Max. Charge Voltage: |
23 V |
| |
Min. Charge Voltage: |
3.6 V |
| |
Amplitude Of Adjustment: |
0.1 V stepping |
| |
Charge Voltage Tolerance: |
± 0.5 V |
| |
Max. Discharge Cut-off Voltage: |
20 V |
| |
Min. Discharge Cut-off Voltage: |
2 V |
| |
Amplitude Of Adjustment: |
0.1 V stepping |
| |
Discharge Voltage Tolerance: |
± 0.03 V |
| Current |
Charge Current: |
0.5 A – 6 A adjustable |
| |
Amplitude Of Adjustment: |
0.1 A stepping |
| |
Charge Current Tolerance: |
± 0.1 A |
| |
Discharge Current: |
0.5 A – 10 A adjustable |
| |
Amplitude Of Adjustment: |
0.1 A stepping |
| |
Discharge Current Tolerance: |
± 0.03 A |
| Charge |
Charge Mode: |
Constant current & voltage charge |
| |
Cut-off Conditions: |
When reaching high constant voltage, the system will automatically switch to trickle charge after charging for 3.5 hours or the charging current is less than 0.3A |
| Discharge |
Discharge Mode: |
Constant current discharge |
| |
Cut-off Conditions: |
Voltage |
| Cycle |
Cycle Mode 1 |
DSCH → IDLE→CHG |
| |
Cycle Mode 2 |
CHG→IDLE→DSCH→IDLE→CHG |
| |
Cycle Mode 3 |
DSCH→IDLE→CHG→IDLE→DSCH→IDLE →CHG |
| |
Cycle Mode 4 |
 CHG→IDLE→DSCH→IDLE→CHG→IDLE →DSCH→IDLE→CHG |
| |
Cycle Mode 5 |
CHG →IDLE→DSCH |
| Pulse Repair |
Pulse Current: |
0.3 A |
| |
Pulse Frequency: |
500 Hz |
| |
Time of Single Repair: |
12 HRS |
| Protection: |
Power-down protection |
| |
Reverse connection protection |
| |
Over-temperature protection |
| |
Over-voltage protection |
| |
Short-circuit protection |
| IP Grade |
IP20 |
| Channel Control Mode |
Independent control |
| High Voltage Insulation Between Channels |
AC1000V/2min Normal |
| Data Display |
LCD |
| Operation Method |
Panel |
| Voltage & Current Test Sampling |
Five-core wires connection |
| Noise |
< 76 dB |
| Upper Computer Communication |
None |
| Communication Port |
None |
| Equipment Work Ambient Conditions |
| Operation Ambient Temperature |
0 ℃ - 40 ℃ |
| Storage Temperature |
-10 ℃ - 50 ℃ |
| Operation Ambient Humidity |
≤ 70 % RH (No condensation) |
| Storage Ambient Humidity |
≤ 80 % RH (No condensation) |