Maintenance Principle
By incorporating the design of isolated channels, each channel is equipped with an advanced processor. This enables precise and independent charging, discharging, and data computation for each battery channel. Parameters from individual cells are collected and analyzed using intelligent algorithms to identify underlying issues within the battery pack. Through controlled methods such as charging, discharging, low charging and high discharging, the voltage consistency across each cell string is ensured, maintaining the voltage difference between cells at a factory-standard level. Consequently, the weak-link effect of the battery pack is mitigated, restoring the overall performance to its original state. Additionally, the equipment features capacity measurement functionality, enabling accurate assessment of the battery's actual capacity. The isolation channel detection technology can pinpoint faulty cells and mark them within the system, providing a reliable basis for efficient battery maintenance. This multi-functional device integrates capacity testing, charging performance evaluation, and balanced maintenance, making it a comprehensive solution for lithium battery pack upkeep.
It’s widely used in battery testing, maintenance, battery repair and rebuilding of new energy electric vehicles.

|
No. |
Descriptions |
|
1 |
Charge |
|
2 |
Discharge (Capacity measurement) |
|
3 |
Auto-cycle charge discharge |
|
4 |
Balance maintenance |
|
5 |
Internal resistance test (DCIR) |
|
6 |
Automatic matching of user-defined criteria |
|
7 |
Test data analysis, comparison, and exporting |
|
8 |
Battery temperature monitoring, control, and alarm |
|
9 |
Parallel channel testing |
|
10 |
Support battery series code scanning identification |

15" HD Touch Screen
Enabling Vivid Data Visualization and Enhancing operational Convenience

Intelligent Equalization Technology
Three Balance Modes
To address the issue of reduced driving range in electric vehicles by providing an effective solution.

Isolated Channel Design With Each Channel Operating Independently
Modular Design & Simplified Maintenance
|
Description: Lithium Battery Charging Discharging Testing and Balance Maintenance Equalizer |
||
|
Model No.: LBS50W-48S |
||
|
Input Voltage: |
AC 220V± 10% 50Hz/60Hz 10A |
|
|
Input Power: |
No-load 15W, full load 2680W |
|
|
Channel Number: |
48 |
|
|
Operation Method: |
15’ touch screen |
|
|
Test Report Output Method |
Excel |
|
|
Cell Detection Connection Method: |
1. Testing cable 2. BMS port (Need balance adapter board) |
|
|
Balance Mode: |
1. Charging balance 2. Discharging balance 3. Charging discharging balance |
|
|
Parallel Channel Testing |
Supports parallel channel testing with a maximum parallel testing current of 160A |
|
|
Parameter of Single Channel |
||
|
Voltage
|
Max. Charge Constant Voltage: |
5V |
|
Min. Discharge Cut-off Voltage: |
1V |
|
|
Tolerance: |
0.02V |
|
|
Current
|
Max. Charge Current: |
10A |
|
Max. Discharge Current: |
10A |
|
|
Min. Charge Cut-off Current |
0.05A |
|
|
Tolerance: |
0.02A |
|
|
Power |
Max. Output Power |
50W |
|
Data Recording
|
Data Recording Conditions
|
Time interval |
|
Voltage interval |
||
|
Current interval |
||
|
Charge
|
Charge Modes:
|
Constant current charge |
|
Constant voltage charge |
||
|
Constant current & voltage charge |
||
|
Charge Cut-off Conditions: |
Voltage, Current, Time, Capacity |
|
|
Discharge
|
Discharge Modes:
|
Constant current discharge |
|
Constant power discharge |
||
|
Constant resistance discharge |
||
|
Charge Cut-off Conditions: |
Voltage, Current, Time, Capacity |
|
|
Parallel Channel Testing |
Supports parallel channel testing with a maximum parallel testing current of 160A |
|
|
Cycle |
Cycle Index: |
1-5000 times |
|
|
||
|
Protection
|
Power-down protection |
|
|
Reverse connection |
||
|
Over-temperature protection |
||
|
Over-voltage protection |
||
|
Short-circuit protection |
||
|
IP Grade |
IP20 |
|
|
Channel Control Mode |
Independent control |
|
|
High Voltage Insulation Between Channels |
AC1000V/2min Normal |
|
|
Voltage & Current Test Sampling |
Five-core wires connection / Probe |
|
|
Noise |
< 76 dB |
|
|
Equipment Work Ambient Conditions |
||
|
Operation Ambient Temperature |
0 ℃ - 40 ℃ |
|
|
Storage Temperature |
-10 ℃ - 50 ℃ |
|
|
Operation Ambient Humidity |
≤ 70 % RH (No condensation) |
|
|
Storage Ambient Humidity |
≤ 80 % RH (No condensation) |
|